American FLUKE is tasted newly roll out - voltage of contact of Fluke 117C blame
From;    Author:Stand originally
Voltage of Fluke 117C blame contact measures avometer

Fluke 117C

    Provide useful Yu Fei to contact the VoltAlert that voltage detects™Technical AutoVolt flows automatically continuously / function of LoZ of alternating voltage choice: Low input impedance, although be in,the LED of wrong reading white that because false voltage is caused,can prevent carries smooth illume on the back the position with weaker light also true virtual value of can effective reading, can be opposite well and truly nonlinear load undertakes metrical measurable 20 A (30 seconds instantaneous; 10 A is successive) resistor, successional, frequency and capacitance measure the least value / maximum / average measures a function, record signal wave to move the human body engineering with compact circumstance to design, suit single hand operation to be able to be used choose the demand of magnetic appearance suspension that match to take (ToolPak™) need not the hand handholds to also can measure safe grade CAT III 600 V

    The surge of 600v of the biggest voltage between terminal of technical standards random and ground protects 6 KV peak value, according to IEC 61010-1 600 V CAT III; Contaminative grade 2 is used at the fuse 11 A that A inputs, 1000 V fast fuse (date of Fu Luke component 803293) indication number: 6000 words, histogram of second of newer rate 4/ 33 paragraphs, c of ° of "-10 of temperature of job of second of newer rate 32/ stores to C of 50 ° C of ° of temperature "-40 comes 9 V of type of cell of C of 60 ° is alkalescent batteries, life of battery of NEDA 1604A/ IEC 6LR61 400 hours (typical cost) , illume of the light that do not have a back

    Accuracy technology standards sheds MV span continuously: 600.0 MV resolution: 0.1 MV accuracy: ± ([% reading] [word] ) : Span of V of 2.0% 3 dc / resolution: Span of 6.000 V / 0.001 V / resolution: Span of 60.00 V / 0.01 V / resolution: Automatic voltage of 600.00 V / 0.1 V chooses span: 600.0 V resolution: 0.1 V accuracy: 2.0 % 3 (dc, 45 Hz comes 500 Hz)
    4.0 % 3 (500 Hz comes 1 KHz) millivolt communicates span of 1 true virtual value: 600.0 MV resolution: 0.1 MV accuracy: 1.0 % 3 (dc, 45 Hz comes 500 Hz)
    2.0 % 3 (500 Hz comes 1 KHz) alternating voltage span of 1 true virtual value / resolution: Span of 6.000 V / 0.001 V / resolution: Span of 60.00 V / 0.01 V / resolution: Accuracy of 600.0 V / 0.1 V: 1.0 % 3 (dc, 45 Hz comes 500 Hz)
    2.0 % 3 (500 Hz comes 1 KHz) successional span: 600ΩResolution: 1ΩAccuracy: Sound warning apparatus<20ΩPut through when, >250ΩShut when; Detect S of 500 μ or longer the open a way when or short circuit. Resistor span / resolution: 600Ω/ 0.1ΩSpan / resolution: 6.000 KΩ/ 0.001 KΩSpan / resolution: 60.00 KΩ/ 0.01 KΩSpan / resolution: 600.0 KΩ/ 0.1 KΩSpan / resolution: 6.000 MΩ/ 0.001 MΩSpan of accuracy 0.9 % 1 / resolution: 40.00 MΩ/ 0.01 MΩAccuracy: Diode of 1.5 % 2 checks span / resolution: Span of capacitance of 0.9% 2 of accuracy of 2.000 V / 0.001 V / resolution: Span of 1000 NF / 1 NF / resolution: Span of F of μ of F / 0.01 of 10.00 μ / resolution: Span of F of μ of F / 0.1 / resolution: Span of μ F of F / 1 of 9999 μ / resolution: Accuracy of F of μ of F To 1000 of 100 μ : 1.9% 2 span / resolution: >Accuracy of F of 1000 μ : 1 NF of span of impedance of 5% 20% low input comes accuracy of F of 500 μ : 10% 2 (typical) temperature 2 (K thermocouple) span / resolution: "- C of 40 ° comes accuracy of C of ° of C / 0.1: 1% 102 span / resolution: "- F of 40 ° comes accuracy of F of ° of C / 0.2: True virtual value of 1% 182 alternating current (45 Hz comes 500 Hz) span / resolution: Span of 6.000 A / 0.001 A / resolution: Accuracy of 10.00 A / 0.01 A: Successive overload of 1.5% 3 20 A 30 seconds (the biggest) span of dc electric current / resolution: Span of 6.000 A / 0.001 A / resolution: Accuracy of 10.00 A / 0.01 A: Successive overload of 1.0% 3 20 A 30 seconds (the biggest) frequency (voltage or electric current input) 2 span / resolution: Span of 99.99 Hz / 0.01 Hz / resolution: Span of 999.99 Hz / 0.1 Hz / resolution: Span of 9.999 Hz / 0.001 Hz / resolution: Accuracy of 50.00 Hz / 0.01 Hz: 0.1% 2